Diagnóstico de madurez pulmonar fetal por velocimetria doppler

Authors

  • Cristian Sosa Sanatorio Internacional, Fundación Fetosur, Unidad de Diagnóstico Avanzado y Cirugía Fetal. Ciudad del Este - Paraguay.
  • Pablo Mascareño Sanatorio Internacional, Fundación Fetosur, Unidad de Diagnóstico Avanzado y Cirugía. Ciudad del Este, Paraguay.
  • Maria Teresa Piris Universidad Nacional del Este, Facultad de Ciencias de la Salud, Centro de Investigación Médica. Minga Guazú, Paraguay.
  • Petronilo Sosa Sanatorio Internacional, Fundación Fetosur, Unidad de Diagnóstico Avanzado y Cirugía Fetal. Ciudad del Este - Paraguay.

DOI:

https://doi.org/10.18004/anales/2019.052(01)25-032

Keywords:

Maximum speed, Ductus arteriosus, Pulmonary maturation, Fetal well-being, Paraguay

Abstract

Objective: To establish the relationship between the gestational age and the maximum velocity of the ductus arteriosus (VmxDA), and to determine if it is possible to predict the fetal lung maturity with Doppler flow assessment of the VmxDA. Study design: A prospective, cohort study was conducted with non-probabilistic sampling where healthy patients who met the inclusion criteria were taken as a population. The maximum velocity of the ductus arteriosus was evaluated. Parametric values were estimated and the coefficient of regression and correlation, sensitivity and specificity was evaluated with gestational age. A 95% confidence interval was used, the different maximum ductus arteriosus velocities were obtained according to gestational age, and their respective standard error along with their standard deviations and they were correlated with gestational age, to determine the possibility of predicting lung maturity by flow assessment of the VmxDA. Results: 824 patients were evaluated where it was evidenced an increase in the maximum velocity of the ductus arteriosus was observed as gestational age progressed. Two inflection points were found in the VmxDA curve at 28 weeks and at 35 weeks. A correlation coefficient of 0.97 was obtained with a probability level of less than 0.0001. The values of sensitivity and specificity to predict lung maturity were 83.9% and 100% for 95 cm / s and 91.5% and 100% for 98 cm / s, with a PPV of 0.709 and a NPV of 1.0. The interobserver variability was less than 5% for the VmxDA. Conclusions: There is a direct relationship between gestational age and the maximum velocity of the ductus arteriosus, which can be used as a good predictor of fetal lung maturity. 

References

1. Torvid Kiserud et all. The fetal circulation. Prenatal Diagnosis 2004;24:1049-1059.

2. Gunther Mielke et all. Circulatory changes following intrauterine closure of the ductus arteriosus in the human fetus and newborn. Prenatal Diagnosis 1998;18:139-145.

3. C. B. Benson et all. Increasing curvature of the normal fetal ductus arteriosus with advancing gestational age. Ultrasound Obstet Gynecol 1995;5:95-97.

4. G. Mielke et all. Blood flow velocity waveforms of the fetal pulmonary artery and the ductus arteriosus: reference ranges from 13 weeks to term. Ultrasound Obstet Gynecol 2000;15:213-218.

5. G. Mielke et all. Reference Ranges for two dimensional echocardiographic examination of the fetal ductus arteriosus. Ultrasound Obstet Gynecol 2000;15:219-225.

6. K. Harada et all. Two dimensional echocardiographic

evaluation of ventricular systolic function in human fetuses with ductal constriction. Ultrasound Obstet Gynecol 1997;10:247-253.

7. Giorgio Pardi et all. Human fetal growth and organ development: 50 years of discoveries. Am J Obstet Gynecol 2006;194:1088-99.

8. Moreno-Alvarez O, Hernandez-Andrade E, Oros D, Jani J, Deprest J, Gratacos E. Association between intrapulmonary arterial Doppler parameters and degree of lung growth as measured by lung-to-head ratio in fetuses with congenital diaphragmatic hernia. Ultra-sound Obstet Gynecol 2008;31:164–170

9. Azpurua H, Norwitz ER, Campbell KH, et al. Acceleration/ejection time ratio in the fetal pulmonary artery predicts fetal lung maturity. Am J Obstet Gynecol 2010;203:e1–e8

10. Fuke S, Kanzaki T, Mu J, et al. Antenatal prediction of pulmonary hypoplasia by acceleration time/ejection time ratio of fetal pul-monary arteries by Doppler blood flow velocimetry. Am J Obstet Gynecol 2003;188:228–233

11. Mitchell JM, Roberts AB, Lee A. Doppler waveforms from the pulmonary arterial system in normal fetuses and those with pulmo-nary hypoplasia. Ultrasound Obstet Gynecol 1998;11:167–172.

12. Laudy JA, Gaillard JL, vd Anker JN, Tibboel D, Wladimiroff JW. Doppler ultrasound imaging: a new technique to detect lung hypoplasia be-fore birth? Ultrasound Obstet Gynecol 1996; 7:189-92.

13. Mitchell JM, Roberts AB, Lee A. Doppler waveforms from the pulmonary arterial system in normal fetuses and those with pulmonary hy-poplasia. Ultrasound Obstet Gynecol 1998; 11:167-72.

14. Achiron R, Heggesh J, Mashiach S, Lipitz S, Rotstein Z. Peripheral right pulmonary artery blood flow velocimetry: Doppler sonographic study of normal and abnormal fetuses. J Ultra-sound Med 1998;17:687-92.

15. Yoshimura S, Masuzaki H, Miura K, Muta K, Gotoh H, Ishimaru T. Diagnosis of fetal pulmo-nary hypoplasia by measurement of blood flow velocity waveforms of pulmonary arteries with Doppler ultrasonography. Am J Obstet Gynecol 1999;180:441-6.

16. Fuke S, Kanzaki T, Mu J, et al. Antenatal prediction of pulmonary hypoplasia by acceler-ation time/ejection time ratio of fetal pulmonary arteries by Doppler blood flow velocimetry. Am J Obstet Gynecol 2003;188:228-33.

17. Seppanen M, Kaapa P, Kero P. Acute ef-fects of synthetic surfactant replacement on pulmonary blood flow in neonatal respiratory distress syndrome. Am J Perinatol 1994;11: 382-5.

18. Hamdan AH, Shaw NJ. Changes in pulmo-nary artery pressure during the acute phase of respiratory distress syndrome treated with three different types of surfactant. Pediatr Pulmonol 1998;25:191-5.

19. Sosa-Olavarra A, Diaz-Guerrero L. Indice relative de impedancia Doppler de la arteria pul-monar y del ductus arterioso en embarazos pretermino, a terminio y post-termino. Revista de Obstetrica y Ginecologica de Venezuela 2000;60:97-101.

20. Van de Mooren K, Barendregt LG, Wladimiroff J. Flow velocity waveforms in the human fetal ductus arteriosus during the normal second trimester of pregnancy. Pediatr Res 1991;30:487-490

21. Snyder, J. M., Mendelson, C. R., & Johnston, J. M. “The morphology of lung development in the human fetus.,” in Pulmonary Development - Transition from Intrauterine to Extrauterine Life., G. H. Nelson, ed., Basel: Marcel Dekker, Inc., New York. 1985, pp. 19-46.

22. Kim SM, Park JS, Norwitz ER, Hwang EJ, Kang HS, Park CW, Jun JK. Acceleration time-to ejection time ratio in fetal pulmonary artery predicts the development of neonatal respiratory distress syndrome: a prospective cohort study. Am J Perinatol. 2013 Nov;30(10):805-12.

23. Thuring A, Malcus P, Maršál K. Effect of maternal betamethasone on fetal and uteroplacental blood flow velocity waveforms. Ultrasound Obstet Gynecol. 2011 un;37(6):668-72.

24. Schenone MH, Samson JE, Jenkins L, Suhag A, Mari G. Predicting fetal lung maturity using the fetal pulmonary artery Doppler wave acceleration/ejection time ratio. Fetal Diagn Ther. 2014;36(3):208-14.

Downloads

Published

2026-09-14

How to Cite

Diagnóstico de madurez pulmonar fetal por velocimetria doppler. (2026). Anales of the Faculty of Medical Sciences, 52(1), 25-32. https://doi.org/10.18004/anales/2019.052(01)25-032